Products

25 Ton Per Day Wood Pellet Production Line for Biomass Fuel Pellets
video
25 Ton Per Day Wood Pellet Production Line for Biomass Fuel Pellets

25 Ton Per Day Wood Pellet Production Line for Biomass Fuel Pellets

Complete 25 MT/Day wood pellet production line for processing sawdust, wood chips into biomass fuel pellets. Stable operation, customized design for wood pellet manufacturing.

Features

 
Quick answer
A 25 ton per day wood pellet production line for biomass fuel pellets is a 1.04 t/h duty over 24 hours or a 3.13 t/h duty over 8 hours, and shift length sets the press frame before anything else is priced. The 24 hour route uses a 90 kW ring die frame and totals about 280 kW installed; the 8 hour route uses a 250 kW frame and totals about 442 kW. Both totals are Illustrative nameplate sums. Six finished fuel fields, the conversion rate, the building area, the clear height and the line weight stay open on the factory technical confirmation sheet.
▪
25 t/day equals 1.04 t/h at 24 h, 1.25 at 20 h, 1.56 at 16 h and 3.13 at 8 h.
▪
Installed power runs about 280 kW on the 24 hour route and about 442 kW on the 8 hour route, both Illustrative.
▪
Electricity works out at about 86.5 kWh/t at the press alone, 269 kWh/t for the whole line and 188 kWh/t at 70% load, all three Illustrative.
▪
Every frame covers the 4-12 mm die range, so 8 mm and 10 mm are a die order rather than a machine order.
▪
GCV, NCV, moisture, ash, bulk density and durability are held to confirmation; no third party threshold is quoted as a promise.

ring die wood pellet making production line

ring die biomass fuel Pellet making production line

01

How Is 25 Tonnes Per Day Converted Into an Hourly Rate?

 

How to read tonnes per day as an hourly figure

A daily tonnage is divided by running hours, not calendar hours, and the gap between the two is the whole sizing decision. Twenty-five tonnes across a full day is a small machine; the same tonnage inside one shift is a large one.
- 25 t/day over 24 h =  - 25 t/day over 20 h =  - 25 t/day over 16 h =  - 25 t/day over 8 h = 
All four are finished product weighed after cooling and sieving, not intake tonnage and not press tonnage before the die. At 300 working days the 24 hour route passes 7,500 tonnes a year, at 330 days 8,250 tonnes. The 25 MT/day target therefore describes the bagging end of the line, and every upstream station is sized from it by division.
Related
the 1 t/h large biomass pellet line reference runs the same arithmetic at a bigger hourly rate.
 

The 1.04 to 3.13 t/h band by shift length

The hourly figure picks the frame before any other choice is made. 1.04 to 1.25 t/h sits inside the 1-1.5 t/h band, so the smallest ring die frame holds a 24 hour duty at the lower end of its band. 1.56 t/h steps up to the 1.5-2 t/h band. 3.13 t/h fits neither and belongs on the 3-4 t/h frame with a 250 kW drive.
The trade shows in one number. Daily tonnage is identical, yet connected power runs from about 280 kW to about 442 kW because the same work is compressed into a third of the hours. An 8 hour route buys a shorter building and fewer staffed hours and pays for that in transformer capacity and peak demand. A 25 tpd plant on a 24 hour route also tolerates a boiler that draws fuel unevenly, because the line runs at part rate while the furnace is down. Neither route is automatically right, and the choice goes on the confirmation sheet rather than being assumed.

ring die sawdust pellet production line

 

 

02

Which Machines Run in Sequence to Reach 25 Tonnes Per Day?

 

Station capacity band along the chain

The chain has seven stations: crushing, conveying, drying, pelleting, cooling, sieving and bagging. The complete biomass line held in this catalogue runs five of them, crushing then conveying then pelleting then cooling then bagging. Drying and sieving are added for this order, because the chips arrive wet and a boiler feed wants a screened product.
Related
the wood pellet production line overview sets out those five core stations, which shows which two rows below are specific to this mill.
Step
Core machine
Model
Power
Rated capacity
Crushing
Wood chip crusher
MK-1500
110 kW
8000 kg/h
Conveying
Screw feeders, 2 units
KWX50YP / KWX150YP
1.5 + 4.0 kW
0-1000 and 0-2000 kg/h
Drying
Single shell rotary dryer, 1.6 x 16 m
-
18.5 + 37 kW
to be confirmed, moisture dependent
Pelleting
Ring die press
MKLH560
90 kW
1-1.5 t/h
Cooling
Counterflow cooler
NKSL11x11
5.5 + 2.1 kW
1000-3000 kg/h
Sieving
Cooling and sieving unit
LX-LS50
8 kW
800-1000 kg/h
Bagging
Automatic weighing and bagging scale
DCS-Z-W-50
3 kW
260-300 bags/h, 10-50 kg
 Capacities are nameplate ratings. The drying row is the only one without an hourly figure, because a drum is sized by evaporation load, which follows incoming moisture rather than tonnage. Two rows deserve comment: the sieve band ends at 1,000 kg/h, just under a 1.04 t/h duty, so it runs with a surge bin ahead of it or is doubled with a second 8 kW machine; the crusher works in campaigns, which is why a 110 kW drive sits in a list scaled to one tonne an hour.
 

Where Buffer Capacity Belongs

A one page process flow sheet travels with the quotation: seven boxes from crushing to bagging, the two buffer points marked, and the rated capacity of each box written under it, so the flow can be checked against this table line by line. Two buffer points belong in the layout, one after the dryer and one before the press. The first absorbs campaign running: a drum that stops for a wet load does not stop the press if four hours of dry material sits between them. The second absorbs grind variation, because ground material of uneven fineness passes a die at an uneven rate. Buffer volume equals two to four hours of press throughput, which at 1.04 t/h is 2 to 4 tonnes, and both positions are marked on the general arrangement drawing issued with the quotation.

ring model biomass granulator production line 

03

How Much Total Installed Power Does This Configuration Draw?

 

Per station power band

 Both are sums of motor ratings in the equipment list, and both are marked . The summary is drawn on the 24 hour route, as a share of 280 kW.
Segment
Rated power, configuration A
Share of total
Crushing
110 kW
39%
Drying, fan and drive
18.5 + 37 = 55.5 kW
20%
Pelleting
90 kW
32%
Cooling
5.5 + 2.1 = 7.6 kW
3%
Sieving
8 kW
3%
Bagging
3 kW
1%
Conveying
5.5 kW
2%



Crushing and pelleting take 71% of the connected load between them. Everything downstream of the press, from cooler to bagger, sums to 24.1 kW, which is why the closing machines rarely trigger an upgrade.
Related
the pellet machine specification sheets carry the drive rating and die range for each frame, which is where the 90 and 250 kW entries are checked.
 

What the Nameplate Sum Leaves Out

Sum the rows, then add what is not in the table. Dust collection fans, compressed air for the bagger at 0.6-0.8 MPa and 0.2 Nm3/min, lighting and wiring losses all sit outside both totals. The transformer is sized on the total plus the starting current of the largest motor: a 250 kW drive started direct on line draws several times its rated current for the seconds it takes to accelerate; a star-delta or soft starter changes that figure but not the running total. Transformer capacity and cable size are confirmed on the customer side of the supply.
Four rows separate the two configurations, so the choice stays open until the fuel draw is known.
Item
Configuration A
Configuration B
Running hours per day
24 h
8 h
Hourly rate needed
1.04 t/h
3.13 t/h
Press frame
90 kW, 1-1.5 t/h
250 kW, 3-4 t/h
Cooler
5.5 + 2.1 kW, 1000-3000 kg/h
7.5 + 2.3 kW, 2000-5000 kg/h
Total installed power, Illustrative
280 kW
442 kW
Energy at nameplate, Illustrative
269 kWh/t
141 kWh/t
Bagging hours per day
21 to 24
7 to 8
The gap is 162 kW, or 58%, for identical daily output. That is the price of a single shift, and it is decided by how the boiler draws fuel rather than by anything in the machine list.
04

How Is Electricity Consumption Per Tonne of Pellets Estimated?

 

Which Load Factor Applies

Electricity per tonne can only be stated as an arithmetic basis, and three bases answer three different questions.
- Press only, nameplate: 90 kW divided by 1.04 t/h =  - Whole line, nameplate: 280 kW divided by 1.04 t/h =  - Whole line at 70% average load: 280 x 0.7 divided by 1.04 = 
All three are . None is measured and none is a guarantee. A measured figure comes from a trial run with a meter on the incoming supply, recorded with the die size, the moisture at the press inlet and the tonnage passed, because a kWh per tonne number without those three values cannot be compared. Use the press-only figure to compare presses, the nameplate figure to size cable, and the 70% figure to plan a bill.
 

Nameplate versus load factor

The nameplate basis runs high for two reasons, neither of them the press. The crusher works in campaigns, so its 110 kW is spread across a fraction of the running hours. The dryer's fans and drive are sized for the wettest incoming load of the year rather than the annual average. A press drawing 90 kW at 1.04 t/h runs at 69 to 104 percent of its 1-1.5 t/h band, so the nameplate figure is not a large overstatement.
One correction belongs in the budget. Drying energy is mostly thermal, and the 55.5 kW on the dryer row is fan and drive power alone; heat for evaporation is a separate account on the thermal side.
05

What Chip Size and Moisture Can Enter the Plant Inlet?

 

Inlet moisture and chip size band


On the dryer side the figures on record are an inlet range of 10% to 80% and an outlet set at 15%, for the rotary family. Those describe what the drum accepts, not what the press wants. For the press the inlet window is , and no number may be borrowed from a neighbouring family: the 12%-20% inlet moisture printed for the feed ring die range belongs to feed milling and does not transfer to wood chip.
Chip size reads the other way. The largest crusher frame opens at 45 cm, so 45 cm is the mechanical limit at the plant inlet, and the die sets the bottom of the range by wanting ground material. The fineness band at the press inlet is to be confirmed on the same sheet; the crusher fixes the top of the range, the die the bottom, and one grinding pass closes the gap.
Related
the sawdust wood pellet line process chain shows how that gap is closed on a line built around dry material, where the crusher alone is enough.
 

How to judge a dryer requirement

Sample three consecutive loads, weigh each, dry each and record the moisture. Above the 15% outlet figure drying belongs in the scope; at or below the press window the drum drops out and the quotation shortens by one station and 55.5 kW. On this material the dryer stays.
The water load follows a mass balance on dry solids: intake in t/h equals finished t/h multiplied by (100 minus outlet moisture %) and divided by (100 minus inlet moisture %). At 1.04 t/h finished, a 35% inlet and a 15% outlet, that gives 1.36 t/h of intake and about 0.32 t/h of water to evaporate. The 35% is a placeholder for the mill's own average, and the figure ignores handling loss.
Next step
confirm chip size and boiler fuel specification together with those three moisture readings, and the dryer duty, press window and die order come back on one sheet.
06

Which Pellet Diameter Suits a Gypsum Board Boiler, 8 mm or 10 mm?

 

Who Settles the Diameter

The diameter is settled at the boiler, not at the press. Three boiler details decide it: the type of fuel feeder, the gap at the grate, and the throat of the burner. A stoker with a narrow grate and a long 10 mm pellet can bridge across it; a feeder set for 10 mm can rattle when fed 8 mm. Those values come from the mill's boiler manual and are the first line on the confirmation sheet.
Reference
IEA Bioenergy Task 32 on biomass combustion covers how grate and feeder design interacts with pellet diameter.
What can be stated from this side is availability. Every frame takes die holes from 4 to 12 mm, so neither diameter forces a machine change.  The quotation states which dies it carries. Which pellet a given furnace burns best is settled at the furnace.
 

Die range 4-12 mm

Model
Capacity
Power
Die hole range
Weight
MKLH560
1-1.5 t/h
90 kW
4-12 mm
5.2 t
MKLH560A
1.5-2 t/h
132 kW
4-12 mm
5.6 t
MKLH700
2-2.5 t/h
160 kW
4-12 mm
7.2 t
MKLH860A
3-4 t/h
250 kW
4-12 mm
9.5 t
Because the range is shared, the die decision survives a frame change: a mill that buys the 90 kW frame now and the 250 kW frame later keeps the same die stock. Two sets belong in the first order, and a comparison run settles the choice - burn half of the first month on each, log feeder behaviour, ash pit and flue reading, keep the die that wins on that furnace. A die cannot be re-bored to another hole size in service, so a second diameter is always a second die. A 10 mm die passes more per hour than an 8 mm die on the same frame, so the 8 mm figure is the conservative one for a commitment.
Related
the ring die press options for boiler fuel list die and roller combinations per frame, which is where the second diameter is ordered from.
07

What Building Area, Clear Height and Total Weight Must Be Planned?

 

Footprint envelope from machine dimensions

The published dimensions set the envelope. The 24 hour press measures 2620 x 1640 x 1770 mm, the 8 hour press 3150 x 1550 x 2240 mm. The largest crusher occupies 2.6 x 1.5 x 1.6 m, the counterflow cooler 1250 x 1250 x 1300 mm and its larger version 2550 x 1550 x 1350 mm, the bagging scale 1200 x 1200 x 2400 mm. The dryer is the long item: a 1.6 m diameter drum, 16 m long, laid horizontally.
 They follow a layout rather than a machine list, so what can be done first is an arrangement drawn on those footprints: machines in line, 1.2 m maintenance aisles on the drive side, 2 m between the hot end of the dryer and the press, a raw store sized on incoming load and a finished store sized on boiler draw.
Related
the biomass pellet line layout reference shows a comparable arrangement on a site plan, including the space the drying section takes.
 

The decision rule for clear height

Clear height is set by the highest fixed point plus room to lift a part out of it. The bagging scale reaches 2400 mm, the 8 hour press 2240 mm, and a feed hopper above either stands higher than the machine it serves. The rule is the tallest assembly, plus the length of the longest part that comes out vertically, plus 500 mm of handling space.
Weight is a foundation question rather than a shipping one: the 24 hour press is 5.2 t and the 8 hour press 9.5 t, and a 16 m drum carries its load through trunnions rather than a flat pad. Slab thickness, plinth positions and anchor layout are civil work confirmed against the drawing.
08

Which Dryer Family and Heat Source Fit a 25 Tonne Per Day Plant?

 

Four dryer families by size

- Airflow: three sizes at 4, 7.5 and 7.5 kW, occupying 7.5 x 1.5 x 3 m, 13 x 1.5 x 3.5 m and 17 x 1.5 x 3.5 m. - Single shell rotary: ten sizes from 0.8 x 8 m at 4.0 + 7.5 kW to 1.8 x 17 m at 22 + 45 kW, 10-12 mm shell plate. - Three layer rotary: 1.6 x 16 m at 18.5 + 45 kW and 1.8 x 17 m at 18.5 + 55 kW, 12 mm shell plate. - Vertical batch: seven sizes from 50 to 400 kg per batch, heating 5 to 22 kW.
For 1.04 to 1.25 t/h the proportionate range is the single shell band from 1.0 x 10 m at 7.5 + 7.5 kW to 1.2 x 12 m at 7.5 + 7.5 kW, with the 1.6 x 16 m drum at 18.5 + 37 kW entering the quotation when inlet moisture runs high. That is a band rather than a promise: the drum follows evaporation load, which follows the water in the mill's own chips.
 

The decision rule for a heat source

Three sources are available and the choice is economic rather than technical: a gas or oil burner, a biomass furnace, or waste heat ducted from an existing process. , because each follows the water load.
For a gypsum board mill the third option deserves a look before the other two are priced. A board line already runs a thermal process, and a duct from it into the dryer inlet takes the fuel bill out of the drying account. Whether that heat is at a usable temperature, and whether it can be spared during a peak board run, are questions for the mill's own energy balance. Where it cannot be spared, a biomass furnace sized on the same water load is quoted as a separate line.

 

IMG20250721150159

 

09

What Conversion Rate and Fuel Specification Are Confirmed in the Quotation?

 

The decision rule for stating a conversion rate

A conversion rate is finished tonnes divided by intake tonnes, and it only means something when both sides sit on one moisture basis.
Reference
the EIA overview of wood and wood waste as fuel explains the units used when a fuel specification is compared across suppliers.
Conversion = finished t x (100 - finished moisture %) divided by intake t x (100 - intake moisture %)
 The arithmetic is given so the mill can compute its own figure, and so a quotation figure can be checked rather than accepted. Three sampling points fix the inputs: intake weight at the crusher feed, moisture at the crusher outlet, finished weight at the bagging scale with bag count times nominal weight as a cross-check.
 

Specification fields held to confirmation

Field
Status
How it is established
Gross calorific value, GCV
to be confirmed
Laboratory report on a trial run sample
Net calorific value, NCV
to be confirmed
Laboratory report on a trial run sample
Moisture of finished pellet
to be confirmed
Sample dried at the trial, reported with the batch
Ash content
to be confirmed
Laboratory report on a trial run sample
Bulk density
to be confirmed
Measured in a calibrated container at the trial
Mechanical durability
to be confirmed
Tumbler test on a trial run sample
 None is quoted from a standard, and no third party threshold is offered as a commitment. ISO, ENplus and DIN figures describe grades a laboratory certifies; they are not a promise about a fuel made from material nobody has sampled.
What can be promised is the testing route: a sample from the trial run, a stated sample mass, all six fields measured by a named laboratory, the report attached to the shipping documents. For a captive boiler the useful reference is the mill's own combustion trial on the first tonne, which is a second reason to order both dies.
10

How Many Operators Per Shift and What Automation Is Included?

 

Operator count per shift band

, because it follows the configuration and whether drying runs on the same shift as the press.
What can be laid out is the post structure. Three posts cover the chain: intake and crushing, press and cooling, bagging and dispatch. On a 24 hour route they run continuously with a fourth for relief. On an 8 hour route the same posts carry three times the hourly tonnage, so bagging takes two people. A planning band of three to four per shift covers both routes.
 

How Far Automation Actually Reaches

The bagging scale is the automated section: automatic weighing, a conveyor, a sewing head and computer control, with static accuracy of +/-0.1% and dynamic accuracy of +/-0.2%. The press carries a forced feeder and a local panel holding die speed and feed rate at the set point, and local control governs the rest.
 Interlock signals between press, cooler and bagger are agreed per project and written on the sheet; where a mill already runs a plant network, dry contacts for run, stop and fault are the interface. Installation, commissioning and training are provided per project, with the labour split, training days and commissioning sequence confirmed on the same sheet.
11

What Commercial Terms Apply to a CFR Chattogram Shipment?

 

The decision rule for a CFR quotation

A CFR Chattogram price is issued as an `itemised quotation, EXW/FOB basis; CIF or CFR available on request`. The line items are the host machines, the first spare set, export packing, the technical file and the sea freight to Chattogram.  - the most misread term in a CFR enquiry, and cargo cover is quoted separately if the mill wants it.
Three details come from the mill before a CFR figure can be built: confirmation of Chattogram as port of discharge, a preference between container and break bulk, and who handles discharge and inland transport. The request for supporting documents is answered by the same package: a general arrangement drawing, a company profile, technical data sheets, reference projects with photographs and video.
After-sales support is named on the same sheet: the service contact route, the wear part reorder path and the response commitment are stated per project, because a response time offered before the scope is fixed is one the mill will hold the supplier to later.
 

Payment and lead time window

Six commercial fields stay open, each confirmed on the same sheet: country of origin, port of loading, payment terms, lead time, warranty period, and the one year spares and wear parts list. None is printed here, because a term offered before the scope is fixed is one the mill will hold the supplier to later.
Lead time counts from receipt of the deposit and approval of the drawings, not from the enquiry date. Two events sit inside that window: drawing approval, which waits on the mill's civil and boiler data, and the factory test, where capacity is demonstrated on a weighed sample. The one year spares list follows the wear map: one die per diameter, one roller assembly, roller shaft bearings, shaft seals, drive belts and die clamp bolts. Warranty covers frames and drives for a stated period and excludes wear parts.
Related
request a 25 tonne per day configuration and CFR quote with the boiler fuel specification and the three moisture readings attached, and the reply comes back as one itemised document rather than a price.
FAQ

FAQ: 

1
How many tonnes per hour must the press deliver for 25 tonnes per day?
1.04 t/h over 24 hours, 1.25 over 20, 1.56 over 16 and 3.13 over 8. The 1.04 to 1.25 band fits a 90 kW frame rated 1-1.5 t/h; 3.13 t/h requires a 250 kW frame rated 3-4 t/h. The figures are finished product after cooling and sieving.
2
What is the total installed power of a 25 tonne per day line?
About 280 kW on a 24 hour configuration, from 110 kW crushing, 55.5 kW drying, 90 kW pelleting and 24.1 kW across cooling, sieving, bagging and conveying. The 8 hour route swaps in a 250 kW press and a 9.8 kW cooler, giving about 442 kW. Both are Illustrative and exclude dust collection, compressed air and lighting.
3
How much electricity is used per tonne of wood pellets?
Three Illustrative figures: 86.5 kWh/t at the press alone, from 90 kW divided by 1.04 t/h; 269 kWh/t for the whole line at nameplate; and 188 kWh/t at 70% load. None is measured, and a metered trial run supplies the real figure.
4
Should boiler fuel pellets be 8 mm or 10 mm?
The boiler decides, through feeder type, grate gap and burner throat read from its manual, and no suitability warranty is offered either way. Both diameters sit inside the 4-12 mm die range on every frame, so the choice is a die order rather than a machine order.
5
What conversion rate applies from wet chips to finished pellets?
No catalogue figure is held, so the rate is to be confirmed against the factory technical confirmation sheet. The dry basis form is finished tonnes times (100 minus finished moisture) divided by intake tonnes times (100 minus intake moisture).
6
What payment terms and shipping basis apply to CFR Chattogram?
Quotation is itemised on an EXW/FOB basis, with CIF or CFR available on request. CFR Chattogram covers machines, spares, packing, technical file and freight, and excludes insurance, quoted separately. Payment terms, lead time, warranty, origin and port of loading are confirmed per project.

Hot Tags: 25 Ton Per Day Wood Pellet Production Line for Biomass Fuel Pellets, China 25 Ton Per Day Wood Pellet Production Line for Biomass Fuel Pellets manufacturers, suppliers, factory, Commercial wood pellet production line, biomass wood pellet line, Wood chip biomass pellet production line, Pellet fuel production line, homemade sawdust pellet line, wood pellet production plan

You Might Also Like

(0/10)

clearall