The Way To Solve The Shaking Of The Main Shaft Of The Pellet Machine?

                The following is the specific method to solve the shaking of the main shaft of the pellet machine: tighten the locking screw on the main gland, and then start the machine to see if the main shaft is still shaking under inspection. If the spindle is still shaking, remove the main gland, use a copper rod to cushion the spindle, use a sledgehammer to strike the spindle in the direction of the mold, and then remove the spindle sealing cover. Check whether the spindle bearing is intact, the general clearance is too large, remove the bearing and replace it with a new one, and then install the spindle locking in turn.

               In the process of installing the spindle, pay attention to the square position of the inner ring of the spindle bearing in order to assemble the spindle in place. The distance between the end faces on both sides of the spindle and the end face of the rotor should be maintained at about 10 centimeters. If excessive clearance is found, excessive keyway fit clearance, and excessive safety pin fit clearance, the above parts should be replaced. Having said that, check if the main shaft of the wood pellet mill is not wobbling.